Batterij automatische filters - bescherming warmtewisselaar

Battery automatic filters to protect heat exchangers

 

Problem = clogging of the plates heat exchanger
Flow rate = 240 m³/hour
Filter fineness = 500 µm

Solution = Automatic filter in battery formation

Filtratie van gerecupreerd koelwater

Filtration of recovered cooling water

 

Problem = plastic particles in the cooling water (80% -150 micron particles)
Filtration fineness = 100 microns
Flow rate = 900 m³/hour

Solution = automatic backwash filter / self-cleaning TYPE M308P

Aanpassing zakkenfilter

Adjustment bag filter

 

Problem = 24 bolts to loosen / too long for production
Flow rate = 160 m³/hour

Solution = Replacing bolts to quick release system

Recuperatie koelwater

Cooling water filtration

 

Problem = contamination of metal flakes with soap residue in the cooling water
Filtration fineness = 200 microns
Flow rate = 400 m³/hour

Solution = automatic backwash filter / self-cleaning TYPE M312P

Rainwater filtration

 

Automatic self-cleaning basket filter
FILTER TYPE – new version SAF-X-1500
DN50 connection – 50 µm filtration
Max. 25 m³/hour

ontsnapping van koelemulsie nevel in werkruimte

Cooling emulsion mist extraction CNC lathe

 

Problem = escape of cooling emulsion mist in work area
Flow rate = 1675 m³/h TYPE FX5000

Solution = Installation of mist extractor

vervuiling van kunststofdeeltjes en organische stoffen - Verstopping van kranen en sproeiers van slibdrogerinstallatie

Effluent filtration

 

Problem = contamination of plastic particles and organic substances
Clogging of taps and nozzles of sludge dryer plant
Filtration fineness = 200 microns
Flow rate = 120 m³/hour

Solution = automatic backwash filter /self-cleaning TYPE M106LP

Voorkomen verstopping van compressoren door plaatsing paneelfilters

Air filtration

 

Problem = Preventing compressor clogging
Filtration fineness = 100 microns
Total flow rate = 10,000 m³/hour

Solution = placement of panel filters on fresh air intake / filtration outside air

Welke filter heb ik nodig om rivierwater te filteren

River water filtration

 

Problem = pollution organic matter, branches, leaves, sand
Coarse filtration fineness = 9000 microns
Fineness of filtration = 80 microns
Flow rate = 150 m³/hour

Solution = automatic double acting backwash filter / both self-cleaning coarse sieve 9000 µm and self-cleaning fine sieve 80 µm TYPE MF306P

Voorkomen van vetten in afvalwaterstroom

Filtration of wastewater stream

 

Problem = Occurrence of fats in wastewater stream
Filtration fineness = 2000 microns
Flow rate = 1- 4 m³/hour

Solution = install stainless steel metal panel filter on overflow settling pit

Filteren van brokken uit chocolade

Filtering chocolate

 

Problem = chocolate chunks in liquid chocolate
Filtration fineness = 2000 microns
Flow rate = 5 m³/hour

Solution = Food grade basket filter with heating jacket Type AOJSTF

Afzuiging papier label werkt niet goed

Paper label extraction

 

Problem = Malfunctioning paper label extraction
Flow rate 2500 m³/hour

Solution = replace type of filter cartridge with self-cleaning function

Tegenhouden en filteren van vezels uit vloeistoffen

Filtering out fibers

 

Problem = limitation of fiber discharge into canal
Filtration fineness = 100 microns
Flow rate = 60 m³/hour

Solution = installation of stainless steel scraper filter with HELICOIDAL scraper.
Fully continuous self-cleaning system

The helicoidal scraping system was developed specifically for fiber and deformable loads.

Firewater filtration

 

Problem = Prevention of clogging extinguishing system
Filtration fineness = 2000 microns
Flow rate = 250 m³/hour

Solution = Stainless steel basket filter DN200 TYPE FAF200304TF