Cartridge filter depth filtration


  • Construction 100% 316L SS fully electro-polished
  • Ideal for high throughput and low spare parts costs
  • V-Clamp or Rathmann type eyebolt closure
  • In accordance with the PED directive 97/23/CE
  • In accordance with 94/9/CE ATEX directive
  • 1935/2004/CE certification available upon request
  • V-Clamp design suitable for filtration of liquids Gr. 1 and 2
  • Design with Rathmann type eye bolts suitable for both filtration of liquids and gas Gr. 1 and 2
  • Side inlet – outlet at bottom (other nozzle arrangements available as option)
  • Suitable for pressures up to 8 bar (V-Clamp) or 10 bar (Rathmann bolts)
  • Designed for depth patterns of series MHF and MHL or pleated PMHF and PMHL series pleated patterns
  • Suitable for 1 to 3 filter housings up to 40″ long (standard) – arrangement with larger quantity of housings is also available (standard)
  • Housings with reusable stainless steel core available in two versions: welded to the tube plate (standard) or dismountable (optional)
  • O-ring head/hull seal
  • 430 SS adjustable legs (for single housing design only)
  • Hydraulic test on 100% of units produced

  • Max. working temperature: 8 bar @ 80 °C (V-Clamp) – 10 bar @ 100 °C (Rathmann)
  • Construction material:
    • BODY: – 316L SS / 304 SS (optional)
    • V-CLAMP (R): – 316 SS micro cast
    • MICRO CAST HEAD (F): – 316 SS micro cast
    • MACHINED HEAD (M): – 316L SS
    • ADJUSTABLE LEGS:- 430 SS
  • Finish: Internal / external: Electrolytic polishing – Pickling (option)
  • Seals: – EPDM – Silicone – Viton – FEP – PTFE
  • In / Out: – 2″ GAS-M – 2.1/2″ GAS-M – 3″ GAS-M – DN 100 PN 16 – DN 150 PN16
  • Vent: – 3/8″ GAS-F
  • Drain pipe plate: – 1/2″ GAS-F
  • Accessories: – Pressure gauge – Vent valve – Flange connections

DIMENSIONS

Afmetingen kaarsenfilter groot debiet diepte filtratie

Max flow rate intended for 50 μm cartridges.
Pure delta-P 0.15 bar.
Flow rates shown change depending on installed filtration capacity.

[1] “C” dimension adjustable, depending on model selected

Afmetingen kaarsenfilter diepte-filtratie

MAXIMUM WORKING PRESSURE

Maximale werkdruk kaarsenfilter

Where the PED Directive 97/23/EC applies, in the case of hazardous liquids Gr. 1, the max. workload are reduced. For other printings, contact Filtermat Belgium.

TEMPERATURE LIMITATION OF SEALS

temperatuur beperkingen van de dichtingen van de kaarsenfilter

The operating temperature is limited by the fitted seals. For other operating temperatures, refer to the manual.